Common faults of spring safety valve

Release date:2017-04-25 author: click:

1. Leakage of spring safety valve

Under the normal working pressure of the equipment, the leakage between the valve disc and the sealing surface of the valve seat exceeds the allowable level. The reason is: there is dirt between the valve disc and the sealing surface of the valve seat. The lifting wrench can be used to open the valve several times to wash away the dirt; the sealing surface is damaged. According to the degree of damage, it shall be repaired by grinding or grinding after turning; the valve rod shall be bent, tilted or the lever and fulcrum shall be skewed to make the valve core and disc misplaced. It shall be reassembled or replaced; the spring elasticity shall be reduced or lost. The spring shall be replaced and the opening pressure shall be readjusted.

2. Disc frequency jump or vibration of spring safety valve

Mainly due to the spring stiffness is too large. The spring with proper rigidity should be used; the adjustment ring is not adjusted properly, so that the reseating pressure is too high. The position of the adjusting ring should be readjusted; the resistance of the discharge pipe is too large, resulting in excessive discharge back pressure. The discharge pipe resistance shall be reduced.

3. The spring safety valve does not open when it reaches the specified pressure

The reason for this is the inaccurate constant pressure. The compression amount of the spring or the position of the heavy hammer shall be readjusted; the disc and the valve seat shall be stuck. The spring safety valve shall be subject to manual air release or water discharge test regularly; the lever of the lever safety valve is stuck or the heavy hammer is moved. The position of the hammer should be readjusted and the lever should move freely.

4. The valve disc does not return to the seat after the discharge of spring safety valve

This is mainly due to the spring bending stem, valve disc installation position is not correct or stuck. It should be reassembled.

5. the pressure of the spring type safety valve continues to rise after the exhaust

This is mainly because the safety relief capacity of the small flat equipment with small displacement of the selected spring safety valve should be re selected. The proper spring safety valve should be re selected. The valve rod should be re assembled or the spring should be replaced because the valve disc cannot be opened to its proper height due to the incorrect center line of the valve rod or the rust of the spring. If the section of the exhaust pipe is not enough, the exhaust pipe conforming to the safety discharge area should be adopted.

6. Open the spring safety valve under the specified pressure

The main reason is that the constant pressure is not accurate, and the aging spring force decreases. The adjusting screw should be tightened properly or the spring should be replaced